Description

Cables symmetrical,twisted pair,with single copper conductor cross-section from 0,2 to 2,5mm², with the isolation of fire-resistant silicone rubber sheathed in PVC low flammability with low smoke and gas evolution.The shell is orange.
Designed for group use,fixed installations in fire protection systems,including fire alarm systems,warning systems and evacuation,automatic fire extinguishing systems,smoke protection systems,as well as in other important life-support systems,which should keep working in a fire;used indoors and out doors.
The UL listed FPLR type shielded power limited re alarm riser cable is suitable to be use in a vertical runs in signaling & re alarm system. It works in high temperature levels. This cable is constructed with FR-PVC insulation and outer jacket with aluminum and PE tape shielding that meets UL 1666/1424 specications. This cable complies with VW – 1 Flame Test requirements in ANSI/UL 1581. Tested as per ANSI/UL 1666/1424 for ame propagation height of electrical and optical – Fibre Cables Installed Vertically in Shafts
TYPE:
1x2x0.80mm2, 2x2x0.80mm2, 3x2x0.80mm2, 4x2x0.80mm2, 1x2x1mm2, 2x2x1mm2, 1x2x1.5mm2, 2x2x1.5mm2, 1x2x2.5mm2

SPECIFICATION:

FeaturesValuesRules
Conductorsannealed red copper cl. 1CEI EN 60228 (Table 9)
Insulationcera mifiable silicone rubber
Cores colour(blue-red) – (yellow-grey) – (green-brown) – (white-black)DIN VDE 815
Flame protectionglass-fibre tape thickness 0,12 mm
Drain wireannealed tinned copper
ScreenAl/Pet tape thickness 9/23 µm covering > 110%
SheathLSZH compound M1 qualityCEI EN 50363
Sheath colourred RAL 3000
Fire retardantCEI EN 60332-3-24
Flame retardantCEI EN 60332-1-2
Halogen free(< 0,5 mg/g – 0,5%)CEI EN 50267-2-1/2 – IEC 60754-1/2
Low smoke emission(Tras mittance > 60%)CEI EN 61034-2
Fire resistantduration 120 min. at temperature of 830 °C. (- 0 ÷ + 40 °C)CEI EN 50200
Fire resistant(E30/E60)DIN VDE 4102-12
Fire resistantduration 180 min. at temperature of 750 °C FE180IEC 60331-21 – VDE 472-814
DC resistanceaccording toCEI EN 60228 (Table 9)
Rated voltage Uo/U300/500 V
Max voltage550 V
Testing voltage2 kV
Max working temperature90 °C
Max conductor temperature180 °C
Short circuit temperature350 °C
Min. installation temperature0 °C
Bending radiusØ x 10

——Our Feature——

1.Imported equipment with experienced technical team
We have three plant and has 3048 employees which have 206 engineers. Plant has a series of imported production lines including Niehoff copper drawing lines, Troster Germany and Maillefer Finland 500KV VCV lines, stranding machine from Pourtier France, SKET Germany, Caballe Spain, 220KV and 35KV production line plus SIKORA X – RAY 8000 on-line eccentricity measuring unit from Germany
2.Complete certification system
We have gotten ISO 9001, ISO 14001, OHSAS 18001. Plant passed TUV, VDE, UL, CE, SAA, BS etc. certificate.
3.Perfect Production system
Our products cover LV power cable, MV power cable, HV&EHV power cable, ABC cables, ACSR/AAC/AAAC/ACAR/OPGW ,submarine cable, control cable, instrumentation cable, building wire, flexible rubber cable, fire rated cable, renewable cable, solar cable, industrial cable, Lan cable, coaxial cable etc.
4.Perfect Sales service system
We can offer the OEM/ODM service, Multiple products, Skilled Export sale engineer team, Reasonable price, Reliable quality, Friendly service.