What is ACYAbY-F 0.6/1kV Steel Tape Armored Power Cable?

ACYAbY-F 0.6/1kV Steel Tape Armored Power Cable is used to transmit the power supply to power stations. It must be protected against corosive chemicals, chemical solvents and solar radiation. This cable can be installed underground, in air, inside or outside and has a high resistance to mechanical shocks. This is a flame retardant cable.

Construction Details

Conductor

  • Material: Aluminium (class 1 or 2)
  • Types: monowire (re), multiwire (rm)

Insulation

  • PVC type A

Inner Sheath

  • Extruded PVC, black or grey

Armour

  • Blank or zinc-plated cold-rolled steel tape
  • Minimum thickness: 0.2-0.5 mm

Outer Sheath

  • PVC type ST 1 black or grey

Technical Data and Tests

Basic Specifications

  • Conductor type: monowire (re), multiwire (rm)
  • Rated voltage Uo/U: 0.6/1 kV
  • Test voltage: 3.5 kV AC or 8.4 kV DC, 5 min
  • Minimum temperature of cable:
    • Installation: -5°C
    • Operation: -30°C
  • Maximum allowed operating temperature: 70°C
  • Maximum short-circuit temperature: 160°C

Installation Parameters

  • Minimum bending radius:
    • 12 x cable diameter with more than 1 conductors
    • 15 x cable diameter with 1 conductor
  • Maximum tensile strain during installation: max 50 N/mm²

Color Coding

  • 1 conductor: blue or yellow-green
  • 2 conductors: blue, brown; yellow-green, black for section > 10 mm²
  • 3 conductors: brown, black, grey; yellow-green, blue, brown
  • 4 conductors: blue, brown, black, grey; yellow-green, brown, black, grey
  • 5 conductors: blue, brown, black, grey, black; yellow-green, blue, brown, black, grey
  • More than 5 conductors: numbered black conductors; yellow-green and numbered conductors

Applicable Standards

  • Cable: IEC 60502-1
  • Conductors: IEC 60228
  • Insulation: IEC 60502-1
  • Flame retardancy:
    • ACYAbY: EN 50265-2-1 (IEC 60332-1) – burning on a single vertical cable
    • ACYAbY-F: EN 50266-2-4 (IEC 60332-3-25 Cat. C) – burning on a bundle of cables

 

Dimensions and Technical Specifications

No. of conductors x cross section mm² External diameter approx. mm Weight approx. kg/km Max. electrical resistance at 20°C Ω/km Permissible load in air at 30°C A Permissible load in ground at 20°C A
2×4 re 15 340 7.41 30 42
2×6 re 16 400 4.61 38 52
2×10 re 17 470 3.08 52 69
2×16 re 19 580 1.91 70 90
3×4 re 16 370 7.41 27 36
3×6 re 17 430 4.61 34 45
3×10 re 18 515 3.08 47 60
3×16 re 20 640 1.91 63 78
3×25 re 24 860 1.20 82 100
3×35 sm 25 840 0.868 100 120
3×50 sm 28 1070 0.641 125 145
3×70 sm 32 1350 0.443 155 175
3×95 sm 37 2060 0.320 190 215
3×120 sm 40 2430 0.253 220 245
3×150 sm 43 2790 0.206 250 275
3×185 sm 48 3415 0.164 285 310
3×240 sm 55 4310 0.125 340 360
3×25+16 re+re 25 930 1.20/1.91 82 100
3×35+16 sm+re 27 950 0.868/1.91 100 120
3×50+25 sm+re 31 1235 0.641/1.20 125 145
3×70+35 sm+sm 35 1580 0.443/0.868 155 175
3×95+50 sm+sm 40 2020 0.320/0.641 190 215
3×120+70 sm+sm 46 2900 0.253/0.443 220 245
3×150+70 sm+sm 48 3240 0.206/0.443 250 275
3×185+95 sm+sm 54 4050 0.164/0.320 285 310
3×240+120 sm+sm 61 5010 0.125/0.253 340 360
4×4 re 17 420 7.41 27 36
4×6 re 18 490 4.61 34 45
4×10 re 20 580 3.08 47 60
4×16 re 22 735 1.91 63 78
4×25 rm 27 1060 1.20 82 100
4×35 sm 27 1035 0.868 100 120
4×50 sm 31 1330 0.641 125 145
4×70 sm 35 1690 0.443 155 175
4×95 sm 41 2550 0.320 190 215
4×120 sm 45 3020 0.253 220 245
4×150 sm 47 3480 0.206 250 275
4×185 sm 53 4280 0.164 285 310
4×240 sm 61 5450 0.125 340 360
5×4 re 18 480 7.41 27 36
5×6 re 19 560 4.61 34 45
5×10 re 21 670 3.08 47 60
5×16 rm 25 890 1.91 63 78
5×25 rm 29 1250 1.20 82 100
5×35 rm 32 1515 0.868 100 120

 

——Our Feature——

1.Imported equipment with experienced technical team
We have three plant and has 3048 employees which have 206 engineers. Plant has a series of imported production lines including Niehoff copper drawing lines, Troster Germany and Maillefer Finland 500KV VCV lines, stranding machine from Pourtier France, SKET Germany, Caballe Spain, 220KV and 35KV production line plus SIKORA X – RAY 8000 on-line eccentricity measuring unit from Germany
2.Complete certification system
We have gotten ISO 9001, ISO 14001, OHSAS 18001. Plant passed TUV, VDE, UL, CE, SAA, BS etc. certificate.