Description

PV1-F-06/1KV photovoltaic cable
PV1-F photovoltaic cable is a special cable used for solar photovoltaic modules in the system. It has the characteristics of weather resistance, high temperature resistance, and friction resistance. It has a long service life and high-quality oxygen-free tinned copper conductors. To ensure the superior conductive effect, high-performance insulating materials and sheath materials after radiation cross-linking by a high-energy electron accelerator have reliable insulating and mechanical properties.

1500V photovoltaic cable H1Z2Z2-K
H1Z2Z2-K, 1500V DC photovoltaic cable is used in the nominal 1.5KV DC voltage photovoltaic power generation system between the conductor and the conductor, and the conductor and the ground. It is an upgraded product on the basis of the original PV1-F-06/1KV photovoltaic cable. Better anti-aging effect.

PV1-F photovoltaic cable

Model:PV1-FOuter diameter of conductor stranded:2.60mm
Application standard:2 PfG 1169/08.2007Insulation nominal thickness:0.8mm
Conductor material:IEC 60228, Category 5 stranded tinned copper wireSheath Nominal Thickness:0.9mm
Insulation material:Irradiation cross-linked low-smoke halogen-free flame-retardant polyolefinOuter diameter of finished wire:6.1±0.1mm
Sheath material:radiation cross-linked low-smoke halogen-free flame-retardant polyolefinConductor resistance (20ºC):≤5.09Ω/km
Nominal cross section:4mm2 6mm2Working environment temperature ºC:-40~+90
current carrying capacity:5 highHigher conductor temperature:+120ºC
Number of cores:1Reference short-circuit allowable temperature:200ºC5S
Conductor structure:NO./mm 56/0.30Rated voltage:DC: 1.8kv
AC U. /U: 0.6/1kv

H1Z2Z2-K photovoltaic cable

Conductor section0.5mm2-300mm2 (other specifications can be customized);Ambient temperature-40℃ to +90℃;
-40 to +194
ConductorTinned copper stranded wire conforms to EN60228.5 category soft conductorMaximum short-circuit temperature280°C, +536°F
InsulationLow-smoke halogen-free radiation crosslinked polyolefinBending radiusFixed installation>4x;
Mobile installation>5x;
SheathLow-smoke halogen-free radiation crosslinked polyolefinMaterial characteristics
/standards
Fire performance: EN 60332-1-2:2004;
Zero smoke emission: 1EC61034: minimum 60% light transmittance
Rated voltageDC 1.5/1.5kV AC 1.0KVLow fire loadDIN 51900
Test voltage6500V, 50HZ, 5 minutesCertificationEN50618:2014
Temperature class-45℃ to 125℃; -45 to +257Application standardEN50618:2014

Single Core PV1-F Solar Cable

Cross section(mm2)Conductor Construction(n/m)ConductorOD
(mm)
Cable Outer(mm)Resistance Max.(Ω/km)Current Carring Capacity(A)InsulationMin.WallThickness
(mm)
SheathMin.Wall
Thickness
(mm)
1×1.5mm2 solar cable30/0.251.584.9013.30300.670.73
1×2.5mm2 pv cable50/0.252.025.457.89410.670.73
1x4mm2 solar pv cable56/0.32.606.104.75500.670.73
1x6mm2 pv solar cable84/0.33.427.203.39700.80.80
1x10mm2 solar panel cables142/0.34.569.001.95980.90.90
1x16mm2 solar system wiring228/0.35.6010.201.241321.000.90
1x25mm2 photovoltaic cable361/0.36.9512.000.7951761.190.92
1x35mm2 photovoltaic cable276/0.408.7413.82181.201.00

Twin Core PV1-F Solar Cable

Cross sectionmm2Conductor Construction(n/mm)ConductorOD
(mm)
Cable Outer(mm)Resistance Max.(Ω/km)Current Carring Capacity(A)
2 x 1.5mm2 twin core solar cable30/0.251.588.3 ± 0.213.3030
2 x 2.5mm2 two core solar pv cable50/0.252.029.2 ± 0.27.9841
2 x 4mm2 dual core solar cable56/0.32.6012.0 ± 0.24.7550
2 x 6mm2 pv cable wire84/0.33.4213.5 ± 0.23.3970
2 x 10mm2 solar cable wire142/0.34.5617.6 ± 0.21.9598
2 x 16mm2 solar wire228/0.35.6019.8 ± 0.21.24132

Notice
In addition, we have other models and sizes, please contact us if you need, thank you.

——Our Feature——

1.Imported equipment with experienced technical team
We have three plant and has 3048 employees which have 206 engineers. Plant has a series of imported production lines including Niehoff copper drawing lines, Troster Germany and Maillefer Finland 500KV VCV lines, stranding machine from Pourtier France, SKET Germany, Caballe Spain, 220KV and 35KV production line plus SIKORA X – RAY 8000 on-line eccentricity measuring unit from Germany
2.Complete certification system
We have gotten ISO 9001, ISO 14001, OHSAS 18001. Plant passed TUV, VDE, UL, CE, SAA, BS etc. certificate.
3.Perfect Production system
Our products cover LV power cable, MV power cable, HV&EHV power cable, ABC cables, ACSR/AAC/AAAC/ACAR/OPGW ,submarine cable, control cable, instrumentation cable, building wire, flexible rubber cable, fire rated cable, renewable cable, solar cable, industrial cable, Lan cable, coaxial cable etc.
4.Perfect Sales service system
We can offer the OEM/ODM service, Multiple products, Skilled Export sale engineer team, Reasonable price, Reliable quality, Friendly service.

Get a free quote